PET/CT Scanner Service Cost Price Info

Like any other piece of medical imaging equipment in your facility, you rely on your PET/CT scanner to serve the diagnostic needs of your patients. And just like any other piece of medical imaging equipment, your PET/CT is going to need periodic maintenance and repair to make sure it stays in service as much as possible. We'll be frank: quality service coverage isn't cheap, but there are ways to save on your service purchase- namely, working with an independent service organization (ISO).

Being an imaging equipment ISO ourselves, we've compiled below-current average price ranges for one year of full PET/CT service coverage versus typical OEM costs. Individual pricing will vary based on the make, model, and age of your system as well as the service options you choose, but these figures will give you a place to start planning. See more about the types of coverage we offer here.

PET/CT Scanner Service Cost Averages

The ranges in the table below represent average prices for a year of full-service coverage, including preventative maintenance, parts, labor, and engineer travel. Keep in mind that many providers will lower the annual cost when you sign up for multiple years or multiple systems.

Manufacturer System Type Avg. Block Imaging Cost/Year
GE ST $109,000 - $122,000
GE STE $118,000 - $129,000
Philips 6-10 Slice $113,000 - $120,000
Philips 16-64 Slice $126,000 - $140,000
Siemens 6-64 Slice $139,535 - $152,875

 

The Takeaway

If you'd like to get your PET/CT scanner covered with more affordable service, the Block Imaging Service Team is happy to begin working on a custom quote for you right now! Use the button below to tell us about your needs and get pricing information quickly.

 

 