How to Tell if a GE Innova Is an IQ System

The “IQ” suffix on some systems in the GE Innova line of cath labs has caused some confusion over the years. Having an IQ could mean more, or different, table-side controls, a touchscreen interface, and improved PACS integration. However, we've talked to a lot of people wondering exactly which Innova version they have and whether or not they can enjoy the advantages of the IQ platform.

We decided it was time to record the answers and put the question to rest once and for all. Here are some tips you can use to identify whether or not your Innova cath lab system is actually an Innova IQ.

To Be Absolutely Sure

The only sure-fire way to know if your system is an IQ is to look in the software. If your system has had the Unity upgrade, then it is considered an IQ.

To check for the Unity upgrade from your home screen:

• Click on the Swiss Army knife icon in the top bar of the screen and choose "Service" from the drop-down menu

• Wait for the Service User's Interface (also called the SUIF, or "swiff") to load

• When the SUIF has loaded, you should see a table labeled "System Overview"

• Look in the field labeled "DL" for the word "Unity"- if it's there, you have an Innova IQ

Innova_IQ_Software.png

Other Indicators

Tableside Controls

If the controls have a silver handle with a blue base, this is indicative that a system is an IQ. We have, however, seen IQ units with blue handles too. If your controls have blue handles, check for the Unity upgrade in the software to be sure.

IQ_Table_Control.jpg

Central Touchscreen Control

If your system has an Innova Central Touchscreen control, you've probably got an IQ. This control is only compatible with Innova IQ systems.

IQ_Touchscreen_Control.jpg

Cabinet Sticker

On top of the Atlas C1 cabinet, there should be an OEM sticker(s) that indicates if the Unity upgrade has been completed.

IQ_Unity_Upgrade_Labels.jpg

Need More Innova Tips and Info?

If you need to know anything else about Innova cath lab equipment, service, or parts, we can help with any of those too. Use the resources below to keep learning, or to contact us about your next cath lab project. 

How to Find Enabled Software Options on a GE Innova Cath/Angio System

Cath/Angio Lab Service Cost Price Info

GE Innova 3100IQ and Philips Allura FD20 Earn 2019 Best in Class

Wondering which is the best Cath Lab for you?

Picture of Kenn Dextrom

Kenn Dextrom

Kenn Dextrom is the Director of Product Manager at Block Imaging. He aims to provide clear direction and careful planning for Interventional Cath Lab buyers and working with the Block Imaging product team to provide excellent solutions for our customers. Out of the office, he spends most of his time keeping up with his wife and their three energetic sons.