Siemens Artis Zee Cath Lab Tube and Detector Guide

Siemens' Artis Zee digital cath labs are the lastest generation in their interventional radiology line and, just as you'd expect, they offer some areas of growth and change in technology and user experience over their predecessors, the Axiom Artis labs. There is at least one thing, however, that has not changed: there are a lot of different configurations and a lot of different tubes and detectors to go with them.

That's where the guide below comes in! You can refer to the table below for descriptions and part numbers for all the X-ray tubes and detectors used on Siemens Artis Zee digital cath labs.

Artis Zee Tubes & Detectors

Before You Choose a Tube or Detector

Be aware that Artis Zee labs don't have the same naming convention as Axiom labs- the one where there's a three-letter code that tells you how it's mounted and whether it's for cardiac or angiography, à la dFC, dTA, etc. They are all simply known as "Artis Zee".

It's also worth noting that the numbers in the names of the detectors do not correlate with their size, i.e.- the Pixium 4700 is the larger 30cm x 40cm detector, while the Pixium 4800 is the smaller 20cm x 20cm detector. There is a third detector type, the Pixium 4810, which is a 20cm x 20cm detector for use only on systems with magnetic navigation (mag nav).

Detectors for Artis Zee Cath Labs

When selecting a detector, note that some detector types are intended to work with certain features like DSA or Mag Nav. If your system has these features, be sure your next detector supports them!

System(s) Detector Type Part Number
Artis Zee Floor, Ceiling, Multi-Purpose Pixium 4700 High Speed 3D 10501945
Artis Zee Floor, Ceiling, Multi-Purpose Pixium 4700 7555209
Artis Zee Floor, Ceiling Pixium 4800 Imp. Interface 10501949
Artis Zee Floor, Ceiling Pixium 4800 DSA 7555308
Artis Zee Floor w/ Mag Nav Pixium 4800 Niobe DSA   03840761
Artis Zee Floor w/ Mag Nav Pixium 4810 Niobe Imp. Interface   10501950


Tubes for Artis Zee Cath Labs

System Tube Type Part Number
Artis Zee Floor Megalix Cat 125/35/80-121GW  5764506
Artis Zee Floor, Ceiling, Multi-Purpose Megalix Cat 125/15/40/80-122GW     5765222
Artis Zee Floor Megalix Cat Plus 125/40/90-121GW  10144181
Artis Zee Floor, Ceiling, Multi-Purpose Megalix Cat Plus 125/20/40/80-122GW  10144184
Artis Zee Ceiling Megalix Cat 125/35/80-122GW    5765040
Artis Zee Floor w/ Mag Nav Megalix Cat 125/35/80-123GW  5765404
Artis Zee Floor w/ Mag Nav Megalix Cat Plus 125/40/90-123GW  10144182


Request Imaging Equipment Parts

Picture of Kenn Dextrom

Kenn Dextrom

Kenn Dextrom is the Director of Product Manager at Block Imaging. He aims to provide clear direction and careful planning for Interventional Cath Lab buyers and working with the Block Imaging product team to provide excellent solutions for our customers. Out of the office, he spends most of his time keeping up with his wife and their three energetic sons.