2008 GE Infinia SPECT (EQ-003921)
3/8 Inch Detectors, Patient table, Variable Angle, Auto Contour, Whole Body / Tomo, 3 collimators - LEHR, MEGP, Pinhole
2006 GE Infinia SPECT (EQ-003910)
3/8 Inch Detectors
Gantry, Patient Table, Workstation
17 Inch LCD Monitor
Collimators with Cart
2016 GE Discovery 630 SPECT (EQ-014130)
Gantry
Whole Body Imaging
Table 500lb patient capacity
3/8" detectors
LEHR and Fanbeam Collimators
Camera evolution for bone
Camera evolution for cardiology
Camera evolution planar bone
Includes Xeleris Workstation
2012 GE Infinia Hawkeye 4 (EQ-003900)
3/8 Inch Detectors, non diagnostic CT tube, Patient table, Variable Angle, Auto Contour, Whole Body / Tomo, Collimator: LEHR, MEGP, Collimator Cart, ECG Gate, Xeleris 3 Workstation
2010 GE Infinia Hawkeye 4 SPECT/CT (EQ-003902)
3/8 Inch Detectors, non diagnostic CT tube, Patient table, Variable Angle, Auto Contour, Whole Body / Tomo, Collimator: LEHR, Collimator Cart, ECG Gate
2010 GE Discovery NMCT 670 SPECT/CT (EQ-003297)
Xray tube replaced on April 2023, MX200CT II Tube, Collimators :, 1x Low Energy High Resolution , Crystal thickness : 3/8, Pixel size : 1.104515, 16 slice CT, Workstation : , Operator's console, DOM: 2016 , SW version 1.003, Xeleris Workstation , SN:CZC34932ST, DOM: 2014, SW version: Xeleris 3.1067, Software disks, manuals and backups included
2015 GE Optima NM/CT 640 SPECT/CT (EQ-000572)
LEHR and MEGP Collimators, Dual Head SPECT/CT, CT tube for Attenuation Correction, Whole Body Imaging, Table 500lb patient capacity, Xeleris 4.0 includes:, Evolution Toolkit, Evolution Cardiac, Evolution Bone SPECT, Enhanced Planar, Cardiac Morphing, ECTB Phase Analysis
2014 GE Optima NM/CT 640 (EQ-013196)
CT tube for Attenuation Correction (New Tube July 2018), Dual Head SPECT/CT, Whole Body Imaging, Table 500lb patient capacity, LEHR, MEGP, Xeleris 4DR Server, Evolution for Bone, Cardiology, Planar Bone
2012 GE Discovery NM/CT 670 SPECT/CT (EQ-003291)
16 Slice Brightspeed CT; Performix Tube replaced Nov 2016, Whole Body Imaging, Table 500lb patient capacity, Collimators: LEHR, GPPH,, Collimator Cart, Software 10BW36.8
2017 GE Discovery NMCT 670 CZT 16 (EQ-003294)
CZT Detectors, 16 Slice Optima 540 CT, Whole Body Imaging, Table 500lb patient capacity, Collimators: WEHUR; , Collimator Cart, Xeleris 4
2018 Siemens Intevo SPECT/CT (EQ-000825)
3/8 inch Foresight detectors
CT for Attenuation Correction
HI_RES, Medium Energy, HI-Energy Colimators
AUTO_CONTOUR, 90_76_ACQUISTION, 180_ACQUISTION, WHOLEBODY, WB_TOMO, ACQUISTION, DISPLAY, PROCESSING, PROCESSING, GET_WORKLIST, 4DMSPECT, SYNGO_GENERAL_LICENSE, FILM_PAPER_PRINTER, FILM_VFS, MPPS_SUPPORT, POST_PROCESSING, CARDIAC_PROCESSING, FUSION, FUSION, ATTENUATION_CORRECTION, Dongle: FlexLM USB, FLASH3D_GENERAL, FLASH3D_CARDIAC, DUAL_MONITORS, BOM ASM AUTO QC, MM_DISPLAY, CT_TOOLBOX, PROCESSING_PLANAR, NUC_SP2_ADV, SPECT_GUIDED_CT, STUDY_SETUP, OUTER_ROOM, GURNEY, GEN_PURPOSE, AUTO_QC, PPM_DISPLAY, SCATTER, CARDIAC_SCATTER, GENERAL_SCATTER, CARDIAC_AC, 4DM SPECT 2013, net Viewer
2017 Siemens Symbia Intevo T6 SPECT/CT (EQ-008636)
Double head, 3/8" Foresight detectors, 2017 Dura 422 tube, Low Energy and Medium Energy Collimators, NMG Auto contour, NMG 90_76 Acquisition, NMG 180 Acquisition, NMG Wholebody, NMG WB Tomo, NMG Acquisition, NMG Display, NMG Processing, Get Worklist, Care Dose, High Speed, Syngo General License, Film Paper Printer, Film VFS, MPPS Support, NMG Post Processing, CAP3D Main, CAP3D Voimode, CAP3D Filter SSD, CAP3D Filter MIP, CAP3D Editor, CAP3D Fusionbase, CAP3D FusionLM, NMG Cardiac Processing, NMG Fusion, RTD, High Power, NMG Attenuation Correction, CAP3D FusionAuto, NMG Flash3D General, NMG Flash3D Cardiac, NMG Dual Monitors, Dual Mon, NMG MM Display, NMG CT Toolbox, NMG porcessing Planar, NC SP6Adv, NMG SPECT Guided CT, NMG Study Setup, NMG OUter Room, NMG Gurney, NMG General Purpose, NMG PPM Display, NMG Scatter, NMG Cardiac Scatter, NMG General scatter, NMG cardiac ac, NMG volume SPECT, Volume workflow, Extended FOV, DICOM SR Viewer, MR support i, NMG recon 3dmm, NMG Adv Acquisition, NMG recon OSCG, NMG QSPECT Acquision, NMG Broad Quant, One head shows hydration
2013 Siemens Symbia T (EQ-013455)
Dual head 3/8 detectors
Emotion Duo with 505k ss
AUTOCONTOUR , 90_76_ACQUISITION, 180_ACQUISITION , WHOLEBODY , WB_TOMO , ACQUISITION , DISPLAY , PROCESSING , GET_WORKLIST , PATREG , CARE_DOSE , HIGH_SPEED , SYNGO_GENERAL_LICENSE , FILM_PAPER_PRINTER , FILM_VFS , MPPS_SUPPORT , 1.3.12.2.1107.5 , CARDIAC_PROCESSING , FUSION , EXTENDED_SPIRAL , HIGH_POWER , ATTENUATION_CORRECTION , ATTENUATION_CORRECTION , FLASH3D_GENERAL , FLASH3D_CARDIAC , NUC_SP2_ADV , SPECT_GUIDED_CT , STUDY_SETUP , OUTER_ROOM , GURNEY , GEN_PURPOSE , EMEDIA , AUTO_QC , PPM_DISPLAY , SCATTER , CARDIAC_SCATTER , GENERAL_SCATTER , CARDIAC_AC , EXTENDED_FOV , DICOM_SR_VIEWER , MR_Support_i
Jan 10, 2022 by Chris Kinnas
If your facility uses a GE Discovery ST or STE PET/CT scanner , you've probably received a letter from GE notifying you...
Oct 1, 2019 by Josh Nunez
It’s been several years since Philips declared their Forte nuclear camera end of life (EOL). Still, through the service...
Jun 6, 2024 by Josh Nunez
When looking for new refurbished equipment on the market, it can be difficult to determine which systems are the latest...