Philips Brightview System Review

Are you looking for a general purpose nuclear camera? One with modern software, reliable detectors, and ready parts availability? Do you have a standing relationship with a Philips-savvy service engineer? To that end, we submit the Philips Brightview for your consideration.

The factors we just mentioned are all good reasons for camera buyers to look into a Brightview, and they're not the only advantages you'll find on its spec sheet, but on top of that the model presents a solid value for Philips-heavy facilities because of the unique moment in which we find the camera market. Keep reading for more on both sides of the Philips Brightview.

Philips Brightview Features and Technology

The Brightview's predecessor, the Forte, was popular all over the world for its reliable detectors, accessible design, and ease of operation. For several years it was one of the most popular cameras we sold. When the Brightview entered the scene in 2007, it was a worthy successor. It retained what was great about the Forte and added a smaller footprint, slightly larger detectors, and a Windows XP-based work environment. Beginning in 2009, you could purchase the Brightview with a flat panel CT detector for attenuation correction which could also capture data for volumetric reconstructions.

The caveat here we want to be clear on is that, like other equipment from Philips, service accessibility for the Brightview is kept much more under lock and key than equipment from some other manufacturers. If your facility uses multiple Philips systems or if you already have a service relationship with an engineer that knows Philips, this might not be a problem. If it isn't a problem, you can take advantage of the next point:

Unique Market Circumstances

In March 2014, Philips suspended indefinitely their CT and molecular imaging manufacturing operations in Cleveland, OH.  This effectively took Philips CTs, PET/CTs, and nuclear cameras off the market until further notice.

In 2016 manufacturing for certain systems began again, but not general purpose nuclear cameras. This left the Brightview, a solidly performing camera, in a kind of orphaned state- relatively young in the equipment life cycle, but no longer rolling off the assembly line. This is good news for buyers. Because the system is no longer manufactured, the cost to acquire one has gone down. At the same time, the third party market has a good supply of systems and parts to keep Brightviews going strong for years to come.

The Takeaway

If you have service partners with the right access, the Brightview can be a good pick for your facility, both in terms of performance and capital cost. If you don't, we'd love to help you find a camera that would be a better fit for your needs. Click the banner below to tell us what you need, ask questions, or request a nuclear camera quote.

Request Nuclear Camera Price

Picture of Josh Nunez

Josh Nunez

Josh Nunez is the Director of Product Management at Block Imaging. Josh is energized by developing an understanding of each customer's unique imaging needs and overcoming the challenge of helping find them the perfect equipment match. When he is not providing PET/CT solutions he enjoys traveling, soccer, and spending time with his wife and five kids.